Home > Products > Power Cable > Mv-90, Rubber Insulated Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072 )
              Mv-90, Rubber Insulated Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072 )
              • Mv-90, Rubber Insulated Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072 )Mv-90, Rubber Insulated Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072 )

              Mv-90, Rubber Insulated Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072 )

              MV-90, Power Cable, 5 KV, 3/C, CU/EPR/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)FeaturesUL Listed as MV-105. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambie......

              Send Inquiry

              Product Description

              MV-90, Power Cable, 5 KV, 3/C, CU/EPR/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)
              Features

              UL Listed as MV-105. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

              Application
              Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

              Standards
              UL 1072: Medium Voltage Power Cables.
              ICEA S-93-639/NEMA WC74: 5 - 46 kV Shielded Power Cables.
              ICEA S-97-682: Standard for Utility Shielded. Power Cables Rated 5 - 46 kV.
              AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 - 46 kV.

              Specifications
              Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL.
              Maximum conductor operation temperatures: Wet and dry locations: Normal: 105 °C, Emergency: 140 °C, Short Circuit: 250 °C

              Engineering Information
              1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
              2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
              3. Insulation: Thermoset ethylene propylene rubber (EPR). On request, Amorphous EPR.
              4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
              5. Phase ID: Colored strings (black, red and blue yarns.)
              6. Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
              7. Grounding (Optional): One or three soft annealed bare copper or covered conductors cabled with phase conductors.
              8. Assembly: Conductors cabled with non hygroscopic fillers, as required and binder tape.
              9. Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.
               
              100% and 133% Insulation Levels (90 mil)
              SizeNumber of StrandsConductor NominalJacket ThicknessApproximate Outside DiameterApproximate Net Weight
              CopperAluminum
              AWG of kcmil
              inmilinlb/kft
              870.13801.15766N/A
              670.17801.23943769
              470.21801.321166889
              270.27801.4414971057
              1190.3801.5117541199
              1/0190.34801.5920291327
              2/0190.381101.7424721589
              3/0190.421101.8429261811
              4/0190.481101.9534492045
              250370.521102.0739662305
              300370.571102.1845432551
              350370.621102.2851212796
              400370.661102.3757343078
              500370.741102.5969463626
              600610.811402.8482814294
              750610.911403.0599314954
              1000611.061403.37127546120

              Related Category

              Send Inquiry

              Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
              Click Refresh verification code

              Leave Your Message

              • Click Refresh verification code