Home > Products > Power Cable > Mv-90, Power Cable, 2.4 Kv, 1/C, Cu/Epr/PVC (ICEA S-96-659/NEMA WC71/UL 1072 )
              Mv-90, Power Cable, 2.4 Kv, 1/C, Cu/Epr/PVC (ICEA S-96-659/NEMA WC71/UL 1072 )
              • Mv-90, Power Cable, 2.4 Kv, 1/C, Cu/Epr/PVC (ICEA S-96-659/NEMA WC71/UL 1072 )Mv-90, Power Cable, 2.4 Kv, 1/C, Cu/Epr/PVC (ICEA S-96-659/NEMA WC71/UL 1072 )

              Mv-90, Power Cable, 2.4 Kv, 1/C, Cu/Epr/PVC (ICEA S-96-659/NEMA WC71/UL 1072 )

              MV-90, Power Cable, 2.4 Kv, 1/C, Cu/EPR/PVC (ICEA S-96-659/NEMA WC71/UL 1072)FeaturesUL Listed as MV-90. Jacket is Listed Sunlight Resistant and Oil Resistant I. Jacket ......

              Send Inquiry

              Product Description

              MV-90, Power Cable, 2.4 Kv, 1/C, Cu/EPR/PVC (ICEA S-96-659/NEMA WC71/UL 1072)

              Features
              UL Listed as MV-90. Jacket is Listed Sunlight Resistant and Oil Resistant I. Jacket is flame retardant.

              Application
              Per NEC, use is limited to 2400 volts maximum. For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.

              Standards

              UL 1072: Medium Voltage Power Cables.
              ICEA S-96-659/NEMA WC71: Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.

              Specifications

              Maximum operating voltage: 2.4 kV in accordance with UL, 5 kV 100%, 3 kV 133% per ICEA
              Maximum conductor operation temperatures: Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C

              Engineering Information
              1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
              2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
              3. Insulation: Thermoset ethylene propylene rubber (EPR).
              4. Grounding (Optional): One or three soft annealed bare copper conductors cabled with phase conductors.
              5. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
              6. Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.
              SizeNumber of StrandsConductor NominalDiameter Over InsulationJacket ThicknessApproximate Outside DiameterApproximate Net Weight
              CopperAluminum
              AWG of kcmil ininmilinlb/kft
              870.1390800.96529-
              670.1790801.03689515
              470.2190801.13891614
              270.2790801.251196755
              1190.390801.311438883
              1/0190.3490801.391695993
              2/0190.3890801.4820111128
              3/0190.4290801.5824361321
              4/0190.48901101.7630321628
              250370.52901101.8835211860
              300370.57901101.9940732082
              350370.62901102.0846302304
              400370.6690.001102.1852212565
              500370.7490.001102.3463062986
              600610.8190.001102.5374143427
              750610.9190.001402.8091684190
              1000611.0690.001403.13119055271