              MV-105, Power Cable, 8 KV, 3/C, Cu/EPR/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

              Features
              UL Listed as MV-105. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

              Application
              Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
              locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

              Standards
              UL 1072: Medium Voltage Power Cables.
              ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
              ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV - 46 kV.
              AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV- 46 kV.

              Specifications
              Maximum operating voltage: 5 kV to 25 kV 100% and 133% IL
              Maximum conductor operation temperatures: Wet and dry locations, Normal: 105°C, Emergency: 140°C, Short Circuit: 250°C

              Engineering Information
              1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
              2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
              3. Insulation: Thermoset ethylene propylene rubber (EPR). On request, Amorphous EPR.
              4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
              5. Metallic Shield: Soft annealed tinned copper tape, 5 mil thick, 25% minimum overlap.
              6. Grounding (Optional): One or three tinned copper or covered conductors cabled with phase conductors.
              7. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
              8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound.
              100% Insulation Levels (115 mil)133% Insulation Levels (140 mil)
              SizeNumber of StrandsConductor NominalJacket ThicknessApproximate Outside DiameterApproximate Net WeightJacket ThicknessApproximate Outside DiameterApproximate Net Weight
              CopperAluminumCopperAluminum
              AWG of kcmil inmilinlb/kftmilinlb/kft
              670.17801.391108174801.5012351061
              470.21801.481343277801.5914771200
              270.27801.61690441801.7118331393
              1190.30801.6719555551101.8522291674
              1/0190.341101.8223647011101.9325261824
              2/0190.381101.927178841102.0228862002
              3/0190.421102318511151102.1233612246
              4/0190.481102.12372414041102.2339092505
              250370.521102.24425816611102.3544522791
              300370.571102.35485119911102.4650543063
              350370.621102.44544523261102.5656553330
              400370.661102.54607026561102.7063843728
              500370.741402.82751033201402.9477524432